2915/2916 Heavy Duty Keypad

Hager

• Stand alone digital keypad

• Designed to control access of a single entry point for facilities with up to 500 users

• Each user assigned a personal identification number (PIN)

• Keypad entry of a valid one- to six-digit code activates one or both of the output relays which releases an electric door lock 

2915

Indoor Keypad - Single Gang

• Indoor blue backlit, moisture-resistant Keypad

• 3/32” (2 mm) thick stainless steel faceplate

• 3 (w) x 4-3/4 (h) x 1-1/2 (d) in

• 1/4” wall extrusion depth

• Available in US3, US4, US10B, US26, US32D

2916

Indoor/Outdoor Keypad - Surface Mount

• Heavy cast vandal resistant housing

• Heavy cast metal blue backlit keys

• 3 (w) x 5-6/8 (h) x 1-7/16 (d) in

• Available in US32D

Features

• 500 users, 1-6 digit PIN codes

• 4 outputs, 2 relay and 2 solid status outputs timed or latching (on/off)

• Assign entry PINs to relays 1 and/or 2

• LED status: access, lockout

• Tactile audible key press, select volume

• Timed anti-passback

• Keypad tamper lockout

• Code activated timed entry PIN disable

• Request-to-exit/enter input, egress Keypad input

• Choice of door sense/relay inhibit input functions

-Forced entry

-Door ajar

-Inhibit relay 1 or 2

-Auto relock when door closes

• Choice of 2 solid status output functions

-Alarm shunt

-Forced entry

-Door ajar

-Tamper lockout

-Keypad active

Specific ations

Voltage: 12/24 VAC/DC

Current: 30 mA typical, 150 mA maximum

Outputs:

Relay 1 - Form “C”, 5 amps @ 28 VDC

Relay 2 - Form “C”, 2 amps @ 28 VDC

Outputs 3 & 4 - switch to common, 100 mA @ 24 VDC

Temperature: -20 degrees F to 130 degrees F -30 degrees C to 54 degrees C

Humidity: 5% - 95% (non-condensing)

 

 

×
EN