2930 Universal Application Electric Strike

Hager

• Heavy duty electric strike

• For new or retrofit construction

• Retrofits existing AN SI 4-7/8” (124 mm) strike prep - no centerline relocation

• Designed for installation in hollow metal frames for access control of cylindrical and mortise locksets and mortise exit devices 

Features

• No centerline relocation

• Up to 3/4” (19 mm) latch bolt and 1” deadbolt

• Field reversible, Fail Safe or Fail Secure

• 1/8” (3 mm) horizontal alignment adjustment

• ANSI/BHMA A156.31 Grade 1

• Factory tested 2500 lbs.

• Exceeded 1,000,000 cycles

• UL tested 1500 lb. static strength

• 70 ft-lb dynamic strength

• Internally mounted solenoid, no heat in keeper

• Dual voltage 12/24 VDC

• Tamper resistant

• All stainless steel corrosion resistant parts and heavy cast body and keeper

• Non-handed (deadbolt status handed)

• Plug-in pig tail connectors

Model

2930-CYL For use with cylindrical locksets

2930-MOR For use with Hager mortise locks

2930-MDB For use with Hager mortise locks with deadbolt

Finishes

US32D Stainless steel (standard)

US4 Dull brass

US10 Dull bronze

US10B Oil rubbed bronze

US26 Bright chrome

US26D Dull chrome

Application

• For use on non-fire rated and fire rated doors (exception, may not be used on stairwell doors)

• May not be maintained in the unlocked (energized) state when used with fire rated doors

• Fail Safe is not permitted with the UL fire door accessory label

Monitoring

• All strikes less monitoring are non handed

• CYL, MOR with monitoring are non-handed

• MDB with monitoring is handed (L-left hand, R-right hand)

• Signals the door is closed and latched or unlatched and open

• Door closed/latched or open/unlatched status

• Access control door adjar/forced entry signal

• Access control anti-tailgate/timer reset signal

• Airlock and interlock logic Door Secure Monitor (DSM)

• Door secure and unlocked monitoring

• Mantraps, interlocks, airlocks Deadbolt Monitoring (DBM)

• Signals deadbolt projected or retracted

• Deadbolt locked/unlocked status

• Occupied signal rooms/bathrooms

• Deadbolt nightlatch monitoring

• Manual lockout of access control by deadbolt

Accessories

BUZZ Plug-in buzzer, 12/24V

Indicates Fail Secure strike is energized and unlocked

(2-679-0028)

RECT Rectifier with wire leads

Converts AC to DC

(2-679-0029)

Electrical Specifications

Dual Voltage: 600/300 mA @ 12/24V DC

Contacts: SPDT, Dry 5 amp @ 30 V DC

Security

UL 1034 Burglary Resistant

BP 10254

40WH

UL10C.3H firerated, 4’ x 8’ door

NFPA 252

CAN 4-5104 (Fail secure only)

 

 

×
EN