2930 Universal Application Electric Strike
Hager
• Heavy duty electric strike
• For new or retrofit construction
• Retrofits existing AN SI 4-7/8” (124 mm) strike prep - no centerline relocation
• Designed for installation in hollow metal frames for access control of cylindrical and mortise locksets and mortise exit devices
Features
• No centerline relocation
• Up to 3/4” (19 mm) latch bolt and 1” deadbolt
• Field reversible, Fail Safe or Fail Secure
• 1/8” (3 mm) horizontal alignment adjustment
• ANSI/BHMA A156.31 Grade 1
• Factory tested 2500 lbs.
• Exceeded 1,000,000 cycles
• UL tested 1500 lb. static strength
• 70 ft-lb dynamic strength
• Internally mounted solenoid, no heat in keeper
• Dual voltage 12/24 VDC
• Tamper resistant
• All stainless steel corrosion resistant parts and heavy cast body and keeper
• Non-handed (deadbolt status handed)
• Plug-in pig tail connectors
Model
2930-CYL For use with cylindrical locksets
2930-MOR For use with Hager mortise locks
2930-MDB For use with Hager mortise locks with deadbolt
Finishes
US32D Stainless steel (standard)
US4 Dull brass
US10 Dull bronze
US10B Oil rubbed bronze
US26 Bright chrome
US26D Dull chrome
Application
• For use on non-fire rated and fire rated doors (exception, may not be used on stairwell doors)
• May not be maintained in the unlocked (energized) state when used with fire rated doors
• Fail Safe is not permitted with the UL fire door accessory label
Monitoring
• All strikes less monitoring are non handed
• CYL, MOR with monitoring are non-handed
• MDB with monitoring is handed (L-left hand, R-right hand)
• Signals the door is closed and latched or unlatched and open
• Door closed/latched or open/unlatched status
• Access control door adjar/forced entry signal
• Access control anti-tailgate/timer reset signal
• Airlock and interlock logic Door Secure Monitor (DSM)
• Door secure and unlocked monitoring
• Mantraps, interlocks, airlocks Deadbolt Monitoring (DBM)
• Signals deadbolt projected or retracted
• Deadbolt locked/unlocked status
• Occupied signal rooms/bathrooms
• Deadbolt nightlatch monitoring
• Manual lockout of access control by deadbolt
Accessories
BUZZ Plug-in buzzer, 12/24V
Indicates Fail Secure strike is energized and unlocked
(2-679-0028)
RECT Rectifier with wire leads
Converts AC to DC
(2-679-0029)
Electrical Specifications
Dual Voltage: 600/300 mA @ 12/24V DC
Contacts: SPDT, Dry 5 amp @ 30 V DC
Security
UL 1034 Burglary Resistant
BP 10254
40WH
UL10C.3H firerated, 4’ x 8’ door
NFPA 252
CAN 4-5104 (Fail secure only)